Owning or managing a warehouse means accounting for all potential hazards. For example, mezzanines in a warehouse or distribution center should be outfitted with guardrails and handrails to minimize the number of falls that occur. Managers must also safeguard against fires in their warehouses.

A warehouse fire is among the worst incidents that can take place in this type of facility. From pallets to goods, many of the items and components that are stored within a warehouse are flammable. If a fire breaks out in a facility that isn’t equipped to handle it, the flames could spread quickly.

Based on the latest statistics from the National Fire Protection Association (NFPA), more than 1,450 warehouse fires are reported every year across the U.S. These events lead to an average of $280 million in property damage, 16 serious injuries, and two deaths every year.

Fire safety codes were introduced in the U.S. and California during the 1980s. Since that time, fire events have decreased considerably in warehouses. While the NFPA has created a comprehensive list of fire codes that warehouses are expected to adhere to, California went a step further.

The California Fire Code (CFC) is a series of regulations that focuses on preventing fires and promoting fire safety in all types of buildings throughout the state. The purpose of this article is to provide detailed information on fire codes that are specific to racking systems in warehouses.

Building on fire

Understanding Fire Codes in California

The California Fire Code (CFC) provides extensive regulations that are similar to the ones within the national fire code. The purpose of this code is to safeguard property and life from the hazards that can be created by fires and explosions as well as hazardous conditions.

Keep in mind that the CFC also consists of provisions that are aimed at assisting emergency response personnel who need to access warehouses after a fire starts. There are several agencies and organizations that are responsible for the California Fire Code, which include CAL FIRE and the National Fire Protection Association (NFPA).

CAL FIRE is a government agency that’s tasked with safeguarding natural resources from fire. They also manage the California forest system and protect the merchantable timber on non-federal lands. As for the NFPA, it’s a nonprofit organization that’s been around since the late 19th century and is focused on eliminating the global losses that occur from electrical and fire hazards. They also create guidelines that often serve as the basis for state fire codes and regulations.

Complying with state fire codes for warehouse safety is of the utmost importance. These are legal requirements that need to be implemented if you want to avoid costly fires. With the right fire suppression systems, you’ll be able to keep your employees safe while also making sure that the spread of smoke and flames is mitigated. Fire suppression systems include everything from smoke detectors and fire alarms to sprinklers.

By taking these regulations seriously, you’ll also be able to preserve your property. Your warehouse is invariably filled with valuable goods, such as machinery, inventory, infrastructure, and vehicles. A fire can damage all these items and set you back thousands of dollars. The California warehouse fire code for racking allows you to limit your losses by ensuring that fires are put out quickly.

Specific Fire Code Requirements for Racking Systems

When you install racking systems in your facility, there are many fire code requirements that you’ll need to follow. For example, racks that are equipped with solid shelving and have an area that’s larger than 20 square feet must meet the fire code requirements in NFPA 13, which focuses on the installation of sprinkler systems. The main exception involves racks with slatted, grated, or mesh shelves. If these shelves cover less than 50% of the total shelf area, the racks don’t need to follow the same guidelines.

When designing your facility’s racking system, make sure that you have at least 18 inches of clearance between the racks and the sprinkler head. If you don’t have any sprinklers in the area, you should maintain two feet of clearance between the racks and the ceiling. When installing ESFR sprinklers, you must achieve 36 inches of clearance.

Keep in mind that ceiling-level sprinklers need to penetrate your pallet racks by accessing open transverse and longitudinal flue spaces. If these spaces are too narrow, the water from the sprinkler system may not reach your inventory or equipment. Based on the California Fire Code, automatic sprinkler systems are often required in warehouses.

In- Rack Fire Sprinkler

If your racking systems have a depth of around 20 feet or less and a maximum height of 25 feet, you may not need to install in-rack sprinklers. Make sure, however, that all transverse flue spaces provide at least three inches of space. If you have a double-row rack system, you need to have at least six inches of flue space through the rack. Some of the additional fire protection guidelines to consider include the following:

  • Three inches of space between multiple pallets
  • Any aisles that have a dead end can’t be lengthier than 50 feet
  • During mechanical restocking, you need to maintain an aisle width of 44 inches
  • The restocking of standard products requires a minimum width of 24 inches, which is around half the aisle width

It’s also important that you don’t exceed the load capacity of your racking system.

Types of Sprinklers

You can outfit your warehouse with many different types of sprinkler systems. When weighing your options, there are several factors to consider, which include your warehouse layout, type of inventory, and storage behavior.

Wet sprinkler systems are among the most common for warehouses and distribution centers. When heat triggers the sprinkler system, water will flow through the pipes before reaching the various heads throughout the warehouse.

Wet pipes are equipped with glass bulbs that will break when the surrounding temperature becomes too high. However, this type of sprinkler isn’t right for every warehouse. If the materials in your facility could be damaged by the water from the sprinkler system, consider another option.

You can also outfit your facility with an in-rack system, which is designed specifically to protect racked areas. These systems constantly monitor for smoke. When the sensors are triggered, water will be released into the target area to ensure damage is minimized. Since these systems are designed to be installed in the middle of racks, they can put out fires quickly and contain the damage to small areas. If you have automated rack structures, this type of sprinkler system may be the best option.

You can also install ESFR wet sprinklers in your warehouse. This system uses Early Suppression Fast Response technology to put out fires in areas with high-piled storage. They are triggered at lower temperatures than other sprinkler systems, which is necessary in warehouses with high ceilings. These systems emit twice as much water as standard wet sprinklers. In fact, they can produce up to 60 gallons per minute. To install this sprinkler system in your warehouse, it’s important that the interior temperatures aren’t below 40 degrees Fahrenheit.

Common Challenges in Complying with Fire Codes

While fire codes are crucial to maintain safety and efficiency in your warehouse, your warehouse operators will need to overcome a few challenges while attempting to get your facility up to code. For example, adhering to the California Fire Code may be more difficult if you need to retrofit equipment and sprinklers into existing racking systems.

Changing the entire layout of your facility is likely too expensive and time-consuming. If you have high-piled storage in your warehouse but don’t have enough room for ESFR sprinkler systems, you might be tasked with making significant changes to your layout to accommodate the new equipment.

Your warehouse operators will also need to ensure adequate water supply and pressure for sprinklers. Once you install the sprinkler system, test it to identify its pressure and water flow. If it’s not up to code, consider installing a booster pump to augment the current pressure levels.

When planning a fire system, you must also maintain clear access and egress routes throughout your warehouse. Make sure you have multiple exit routes, each of which should be as far away from the others as possible. If one route is blocked by smoke or fire, the other routes may be clear.

Solutions and Best Practices for Overcoming These Challenges

While there are numerous challenges that must be taken into account when maintaining health and safety in your warehouse, you can overcome them by consulting with fire safety experts, obtaining regular inspections and maintenance, and implementing employee training. During employee training, your personnel should practice fire drills to ensure everyone knows how to react in the event of a fire.

Warehouse Fire Suppression Systems

Conclusion

The racking system in your warehouse should be designed in such a way that it accommodates any sprinklers you install. You can effectively avoid highly damaging warehouse fires by making sure that you have the equipment in place to put out the flames quickly.

By adhering to the California Fire Code, you can be confident that your warehouse racking is properly spaced. After you enhance warehouse safety through compliance, stay informed about updates to fire codes and regulations. The California Fire Code is based primarily on the International Fire Code, which is updated every three years.